How to identify capacitor malfunction

 

How to identify capacitor malfunctionLoss of performance capacitorsmay occur due to:

i) a short circuit inside it;

b) a chain break inside it;

c) increase in leakage current;

d) decrease in capacity.

An inoperative capacitor can be determined using an ohmmeter, a special device for measuring capacitance, or a test circuit.

For a rough check of the suitability of capacitors, it is recommended to control them using resistance meters (ohmmeter, combined instrument - multimeter).


The verification procedure is as follows:

1) one of the terminals of the capacitor should be separated (soldered) from the circuit;

2) the measuring device is configured to measure in the range of tens and hundreds of kilo-ohms or even megaohms;

3) are applied to the terminals of the capacitor multimeter probes.

In this case, for capacitors of large capacity from several tens to several thousand microfarads, the initial throw of the arrow of the device to “zero” (at the moment of passage of the maximum charge current) with the subsequent deviation of the arrow to the label “infinity” will be characteristic;

4) an ohmmeter reading of at least 100 kOhm will correspond to a satisfactory condition of the dielectric of the capacitor;

5) if an open circuit occurs in a large capacitor (10 - 100 μF), then the arrow of the device is immediately set to the “infinity” mark;

6) for small capacitors, it is almost impossible to determine the presence of an open circuit with an ohmmeter, since the measuring device will show either a short circuit if an insulation breakdown has occurred, or an infinitely large resistance if the capacitor is in good condition or there is an open.



How to identify capacitor malfunctionIf there is a suspicion of a break, such capacitors are usually replaced.

An open circuit inside the capacitor is determined by means of a measurement circuit consisting of a series-connected capacitor, an alternating current ammeter and a resistor that limits the current through the device.

The circuit is switched on to an AC source, the voltage of which should not exceed 20% of the rated voltage of the capacitor. A lack of current in the circuit indicates an open.

The increase in leakage current is determined by reconnecting the ohmmeter to the capacitor terminals.

At the first connection, the arrow of the device deviates due to the charge current, and then returns to its original position.

If during subsequent connections, repeated with an interval of several seconds, the deviations of the arrow are repeated, this means that the capacitor has an increased leakage current.

The decrease in capacity that occurs most often in electrolytic capacitors, is determined by comparing the nominal capacitance with the actual, measured by means of special bridges or circuits and some types of multimeters.

And here is a reader about the intricacies of testing transistors: How to check the transistor

See also at bgv.electricianexp.com:

  • How to determine the malfunction of thyristors
  • How to choose capacitors for connecting a single-phase and three-phase electrode ...
  • Multimeter for "dummies": the basic principles of measuring multime ...
  • How to easily determine the capacitance of a capacitor
  • Polar and non-polar capacitors - what is the difference

  •  
     
    Comments:

    # 1 wrote: Gregory | [quote]

     
     

    I completely agree, but there is still a very simple and affordable way to check the capacitor for a breakdown visually. On the body of punched capacitors, you can detect dark spots, bloating, darkening. When checking electrolytic capacitors, it is necessary to completely discharge the tested capacitor before carrying out a capacitance measurement.Especially this rule should be followed when checking polar capacitors having a large capacity and high operating voltage. If this is not done, then the measuring device can be damaged.

     
    Comments:

    # 2 wrote: Igor | [quote]

     
     

    They also very often ask me how to ring a capacitor. There are really a lot of methods for checking capacitors on the Internet, but they are not suitable for all types of condensers. In fact, a punctured capacitor is the same conductor, thereby making it possible to ring it for resistance. Here, in general, everything is simple. You call for resistance, put it on a 2000 kOM tester, if the number starts to grow, then the conder has flown. But to measure the capacity will not work, this way. The term "ring the capacitor" scares many. But earlier, when they used the * workshop *, the capacitors called exactly, because this method did not determine its capacity, but simply watched whether it takes a charge or not. And it was done simply, applied the probes to the conclusions, then the polarity changed, that is, the probes changed places, and watched how the arrow deviated, and at the same time the arrow should return to its original position, as it was discharged. If the arrow did not deviate at all, or if it did not return, it was dead. Something like this was, And now there are a lot of devices, including combined multimeters.

     
    Comments:

    # 3 wrote: Alexander | [quote]

     
     

    And how to check the trimmer (kpe) from an electronic wristwatch?

     
    Comments:

    # 4 wrote: | [quote]

     
     

    Thank you for the good and necessary articles .. Not everyone has the opportunity to hire a wizard to fix something .... If you can ask a question? What to do if the pneumatic compressor does not have enough power to pump air ??? What to do? I will be very grateful!!!

     
    Comments:

    # 5 wrote: Nikita | [quote]

     
     

    Vladimir,
    the relay which is responsible for limiting the maximum permissible pressure is incorrectly configured try adjusting the bolts ONLY VERY CAREFULLY !!!
    You can also try changing the decompression valve if it releases.

     
    Comments:

    # 6 wrote: | [quote]

     
     

    You can’t see anything broken on non-Russian condos, there is an option to connect the condon to the 220 network through an automatic machine for 1 - 2 amperes, if it does not work, it means good.